Vision VTB-101 Guide de l'utilisateur Page 79

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 125
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 78
79
VTB USER GUIDE
TEMPERATURE READING ON NG35
The NG35 is equipped with a TEMPERATURE SENSOR which can be useful to monitor the internal temperature. The
sensor is connected to the Nr. 9 internal ANALOG CHANNEL and it can be read with the system function ng_adc as for
the other analog inputs. To convert the value in degrees Celsius we have to do a calculation (see example).
Example
Function Read_Temp() as Long
Dim Degrees as Long
Degrees=NG_ADC(8) ' Read the temperature sensor
Degree= Degrees*3300/1024-600 ' Convert the value in 0.1 degrees
Read_Temp= Degrees
EndFunction